Brewery Glycol Chiller - BrewChill Pro 7500 - 7500 BTUs
The BrewChill Pro 7500-2 delivers 7,500 BTU/h of cooling capacity for fermentation and tank temperature control in breweries, wineries and cideries. It combines a 1 HP compressor, an 18-gallon glycol reservoir and two pre-installed 80 GPH vane pumps, each powered by a 1/3 HP motor.
The two-pump package includes two external digital thermostats and four solenoid valves for controlling cooling demand in two tank circuits. Both circuits draw from the same chilled glycol supply and share the unit’s total cooling capacity.
Key Features of BrewChill Pro 7500-2 Glycol Chiller
- 7,500 BTU/h total cooling capacity: Select the chiller based on the combined load of all tanks requiring cooling simultaneously.
- Two pumps included, expandable to three: Supplied with two pre-installed 80 GPH vane pumps, each powered by a 1/3 HP motor, with provision for one additional pump.
- 18-gallon glycol reservoir: Supplies the glycol-and-water mixture circulated through the connected cooling circuits.
- 1 HP compressor with R290 refrigerant: Cools the shared glycol reservoir.
- Glycol line runs up to 450 ft: Suitability depends on tubing size, insulation, elevation, circuit resistance and cooling load.
- 208/230 V, 60 Hz power: Supplied with a NEMA 6-20P plug and a 6-ft power cord. Confirm that your installation location has a compatible electrical supply before ordering.
Parts Included:
- 1 × Glycol Chiller with two pre-installed 80 GPH vane pumps, each powered by a 1/3 HP motor
- 2 x External Digital Thermostats
- 4 × Solenoid Valves
BrewChill Pro 7500 - USA |
|
| MODEL | BC-7500-2 |
| MAXIMUM DISTANCE | Up to 450 ft |
| CAPACITY | 7500 BTU/H |
| GLYCOL TANK CAPACITY | 18 gallons |
| COMPRESSOR POWER | 1 HP |
| RUNNING | With 1 pump - 10.0 AMP With 2 pumps - 12.8 AMP |
| PLUG TYPE (NEMA #) | 6-20P |
| VOLTAGE | 208/230 V |
| FREQUENCY | 60 HZ |
| PUMP TYPE | Vane with 1/3hp motor |
| PUMP | 80 GPH |
| NUMBER OF PRE-INSTALLED PUMPS | 2 |
| NUMBER OF ADDITIONAL PUMPS | 1 |
| REFRIGERANT | R290 |
| REFRIGERANT CHARGE, G (OZ) | 150 (5.29) |
| WEIGHT GROSS/NET | 154 / 147 lb |
| POWER CORD LENGTH | 6 ft |
| INLET/OUTLET BARB, IN | red tube 3/4” NPT / blue tube 3/4” NPT |
| OPERATING AMBIENT TEMPERATURE | 60-90 F |
| CLEARANCE AT LEAST | 12" around the entire unit |
| GLYCOL MIXTURE, VOL% | 40 % glycol and 60% water |
Note: Installation of this item must be handled by a qualified installer in order to qualify for product return and/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services and possesses a business license, contractor's license and/or resale permit. Common examples of a "qualified installer" include Electrician; General Contractor; Heating and Air Conditioning Specialist.
Tank volume alone does not determine the required cooling capacity. Fermentation temperature control, cold crashing and holding a tank cold place different demands on the chiller.
Use our brewery chiller sizing calculator to estimate your cooling load. Include the number and volume of tanks, ambient temperature, target temperature and required cooling time.
For help selecting a configuration or obtaining a US shipping quote, email sales@beveragecraft.com with your tank details and full delivery address.