{"title":"Brewery Chillers","description":"\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eBrewery Chillers for Fermentation \u0026amp; Cold Crashing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eTake control of fermentation temperatures with brewery glycol chillers designed for fermenters and compatible brewing tanks. From maintaining steady temperatures during active fermentation to cooling beer for cold crashing, a properly sized chiller helps you manage each batch with confidence.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eExplore cooling capacities and pump configurations for small brewing setups, commercial breweries, wineries, and cideries. Choose a system matched to your tank volumes, temperature targets, and production schedule.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003eNeed help sizing your brewery chiller?\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e We can schedule a free quote with a technician to review your tanks and cooling requirements. Our team will help you select the right unit and can arrange installation. \u003cmeta charset=\"utf-8\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan\u003e\u003ca href=\"https:\/\/floridabrewing.com\/pages\/contact\"\u003eContact us\u003c\/a\u003e to schedule your free quote.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e","products":[{"product_id":"brewery-chiller-brewchill-pro-13000ss-13000-btus-usa-only","title":"Brewery Glycol Chiller - BrewChill Pro 13000SS - 13000 BTUs","description":"\u003cp\u003eThe BrewChill Pro 13000SS-2 combines a stainless steel housing with 13,000 BTU\/h of cooling capacity for fermentation and tank temperature control. Two 1 HP compressors cool an 18-gallon glycol reservoir that supplies the connected tank circuits.\u003c\/p\u003e\n\u003cp\u003eThe standard package includes two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor, along with two external digital thermostats and four solenoid valves. These components manage cooling demand in two circuits. Both circuits share the reservoir and total cooling capacity, so the combined load must be considered when selecting the chiller.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eStainless steel housing:\u003c\/strong\u003e Provides a stainless exterior for installations where this cabinet material is preferred.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e13,000 BTU\/h total cooling capacity:\u003c\/strong\u003e Size the system for the \u003ca href=\"https:\/\/www.beveragecraft.com\/stainless-steel-tanks\/\"\u003etanks \u003c\/a\u003eand processes requiring cooling at the same time.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo pre-installed vane pumps:\u003c\/strong\u003e Each pump is rated at 80 GPH and has a separate 1\/3 HP motor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo 1 HP compressors with R290 refrigerant:\u003c\/strong\u003e Cool the shared glycol supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18-gallon reservoir:\u003c\/strong\u003e Holds the glycol-and-water mixture circulated through the connected cooling circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlycol line distances up to 750 ft:\u003c\/strong\u003e Actual suitability depends on tubing size, insulation, elevation, circuit resistance and cooling demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/230 V, 60 Hz power:\u003c\/strong\u003e Supplied with a NEMA 6-20P plug and a 6-ft power cord. Confirm that your installation location has a compatible electrical supply.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eParts Included:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Glycol Сhiller with two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor\u003c\/li\u003e\n\u003cli\u003e2 × External Digital Thermostat\u003c\/li\u003e\n\u003cli\u003e4 × Solenoid Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-bordered specification-tab\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch6\u003eBrewChill Pro 13000SS - USA\u003c\/h6\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODEL\u003c\/td\u003e\n\u003ctd\u003eBC-13000SS-2-ASM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXIMUM DISTANCE\u003c\/td\u003e\n\u003ctd\u003eUp to 750 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003e13000 BTU\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL TANK CAPACITY\u003c\/td\u003e\n\u003ctd\u003e18 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMPRESSOR POWER\u003c\/td\u003e\n\u003ctd\u003e1+1HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUNNING\u003c\/td\u003e\n\u003ctd\u003eWith 1 pump - 12.7 AMP\u003cbr\u003eWith 2 pumps - 15.5 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLUG TYPE (NEMA #)\u003c\/td\u003e\n\u003ctd\u003e6-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOLTAGE\u003c\/td\u003e\n\u003ctd\u003e208\/230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREQUENCY\u003c\/td\u003e\n\u003ctd\u003e60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP TYPE\u003c\/td\u003e\n\u003ctd\u003eVane with 1\/3hp motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP\u003c\/td\u003e\n\u003ctd\u003e80 GPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF PRE-INSTALLED PUMPS\u003c\/td\u003e\n\u003ctd\u003e 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF ADDITIONAL PUMPS\u003c\/td\u003e\n\u003ctd\u003e 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT\u003c\/td\u003e\n\u003ctd\u003e R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT CHARGE, G (OZ)\u003c\/td\u003e\n\u003ctd\u003e 150 (5.29)+150 (5.29)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e WEIGHT GROSS\/NET\u003c\/td\u003e\n\u003ctd\u003e 238 \/ 231 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e POWER CORD LENGTH\u003c\/td\u003e\n\u003ctd\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e INLET\/OUTLET BARB, IN\u003c\/td\u003e\n\u003ctd\u003e red tube 3\/4” NPT \/ blue tube 3\/4” NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e OPERATING AMBIENT TEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e 60-90 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CLEARANCE AT LEAST\u003c\/td\u003e\n\u003ctd\u003e 12\" around the entire unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL MIXTURE, VOL%\u003c\/td\u003e\n\u003ctd\u003e40 % glycol and 60% water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNote: Installation of this item must be handled by a qualified installer in order to qualify for product return and\/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services, and possesses a business license, contractor's license, and\/or resale permit. Common examples of a \"qualified installer\" include Electrician; General Contractor; Heating and Air Conditioning Specialist.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTank volume alone does not determine the required cooling capacity. Fermentation temperature control, cold crashing and holding a tank cold place different demands on the chiller.\u003c\/p\u003e\n\u003cp\u003eUse our \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-sizing-calculator\/\"\u003ebrewery chiller sizing calculator\u003c\/a\u003e to estimate your cooling load. Include the number and volume of tanks, ambient temperature, target temperature and required cooling time.\u003c\/p\u003e\n\u003cp\u003eFor help selecting a configuration or obtaining a US shipping quote, email \u003ca href=\"mailto:sales@beveragecraft.com\"\u003esales@beveragecraft.com\u003c\/a\u003e with your tank details and full delivery address.\u003c\/p\u003e","brand":"BeverageCraft","offers":[{"title":"2 Vane Pumps","offer_id":67969959264470,"sku":null,"price":4874.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3668\/1430\/files\/Brewchill_13000_2__28971__50086.1787680694.webp?v=1794504538"},{"product_id":"brewery-chiller-brewchill-pro-3200h-3200-btus-usa-only","title":"Brewery Glycol Chiller - BrewChill Pro 3200H - 3200 BTUs","description":"\u003cp\u003e\u003cspan\u003e \u003cimg alt=\"icon-pdf.png\" class=\"__mce_add_custom__\" height=\"32\" src=\"https:\/\/cdn11.bigcommerce.com\/s-2pml8e\/content\/specification\/Specification_pdf.svg\" title=\"icon-pdf.png\" width=\"32\"\u003e \u003ca href=\"https:\/\/www.beveragecraft.com\/content\/specification\/glycol-chillers\/BC-3200-1-GP.pdf\" target=\"_blank\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eNano breweries and pilot systems in the US often run into the same wall: not enough floor space for a full glycol system, but not enough control from a swamp cooler either. The BrewChill Pro 3200-1-GP solves that with a self-contained 3,200 BTU glycol chiller that fits in a tight corner and still delivers commercial-grade cooling from a 6.3 gallon reservoir mixed to about 40 percent glycol and 60 percent water. Inside, a vane pump moves chilled glycol from the reservoir out to your tank's cooling jacket, and an automatic thermostat keeps the temperature where you set it around the clock.\u003cbr\u003eThe unit handles fermentation tanks up to 200 liters, which covers most pilot batches and early-stage nano brewery setups. And because the cooling process itself doesn't care what's fermenting, this same chiller shows up just as often at small wineries and cideries that need dependable temperature control without a full walk-in cooler.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e3,200 BTU\/h cooling capacity:\u003c\/strong\u003e Enough cooling power for fermentation tanks up to 200L in a compact footprint - ideal for pilot-scale breweries and advanced homebrew setups that need commercial-grade temperature control.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSingle zone vane pump:\u003c\/strong\u003e Ships standard with one 80 gal\/hr \u003ca href=\"https:\/\/www.beveragecraft.com\/pumps-and-motors\/\" target=\"_blank\"\u003evane pump\u003c\/a\u003e (1\/3 HP motor) This model runs a single cooling zone and does not support adding a second pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLow energy use, low noise:\u003c\/strong\u003e A 3\/8 HP \u003ca href=\"https:\/\/www.beveragecraft.com\/compressors-beverage-refrigeration-parts\/\" target=\"_blank\"\u003ecompressor\u003c\/a\u003e running eco-friendly R290 refrigerant keeps power draw and operating noise down without sacrificing performance.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSmall footprint, built to last:\u003c\/strong\u003e Compact enough for tight brewery corners or home setups, with industrial-grade components for long-term reliability.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePlug-and-play U.S. setup:\u003c\/strong\u003e Arrives with 3\/4\" NPT inlet\/outlet barbs, a 6 ft power cord, and a standard NEMA 5-15P plug - no adapters or rewiring needed for U.S. outlets.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong line reach:\u003c\/strong\u003e Glycol lines can run up to 125 ft, giving you flexibility in where you place the chiller relative to your tanks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSteady performance under load:\u003c\/strong\u003e A 6.3-gallon glycol tank paired with the vane pump keeps temperatures stable through long brew days and back-to-back batches.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eParts Included:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × BrewChill Pro 3200-3\/8-GP glycol chiller with 80 gal\/hr recirculation pump (1\/3 HP motor)\u003c\/li\u003e\n\u003cli\u003e1 × External Digital Thermostat\u003c\/li\u003e\n\u003cli\u003e2 × Solenoid Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-bordered specification-tab\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch6\u003eBrewChill Pro 3200H - USA\u003c\/h6\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODEL\u003c\/td\u003e\n\u003ctd\u003eBC-3200-1-GP-ASM-USA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXIMUM DISTANCE\u003c\/td\u003e\n\u003ctd\u003eUp to 125 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003e3200 BTU\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL TANK CAPACITY\u003c\/td\u003e\n\u003ctd\u003e6.3 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMPRESSOR POWER\u003c\/td\u003e\n\u003ctd\u003e3\/8 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUNNING\u003c\/td\u003e\n\u003ctd\u003e13.3 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLUG TYPE (NEMA #)\u003c\/td\u003e\n\u003ctd\u003e5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOLTAGE\u003c\/td\u003e\n\u003ctd\u003e115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREQUENCY\u003c\/td\u003e\n\u003ctd\u003e60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP TYPE\u003c\/td\u003e\n\u003ctd\u003eVane with 1\/3hp motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP\u003c\/td\u003e\n\u003ctd\u003e80 GPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF PRE-INSTALLED PUMPS\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF ADDITIONAL PUMPS\u003c\/td\u003e\n\u003ctd\u003e 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT\u003c\/td\u003e\n\u003ctd\u003e R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT CHARGE, G (OZ)\u003c\/td\u003e\n\u003ctd\u003e 120 (4.23) Secop \/ 80 (2.82) Cubigel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e WEIGHT GROSS\/NET\u003c\/td\u003e\n\u003ctd\u003e 80 \/ 76 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e POWER CORD LENGTH\u003c\/td\u003e\n\u003ctd\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e INLET\/OUTLET BARB, IN\u003c\/td\u003e\n\u003ctd\u003e red tube 3\/4” NPT \/ blue tube 3\/4” NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e OPERATING AMBIENT TEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e 60-90 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CLEARANCE AT LEAST\u003c\/td\u003e\n\u003ctd\u003e 12\" around the entire unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL MIXTURE, VOL%\u003c\/td\u003e\n\u003ctd\u003e40 % glycol and 60% water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003e Note: Installation of this item must be handled by a qualified installer in order to qualify for product return and\/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services and possesses a business license, contractor's license, and\/or resale permit. Common examples of a \"qualified installer\" include Electrician; General Contractor; Heating and Air Conditioning Specialist.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eRun your tank dimensions through our \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-sizing-calculator\/\" target=\"_blank\"\u003ebrewery chiller sizing calculator\u003c\/a\u003e to confirm 3,200 BTU covers your setup before you order. Nano breweries that outgrow this size within the first year usually move up to the \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-brewchill-pro-4000-4000-btus-usa-only\/\" target=\"_blank\"\u003eBrewChill Pro 4000-1\u003c\/a\u003e, which adds more reservoir capacity and cooling power. Not sure which one fits your timeline? \u003ca href=\"mailto:sales@beveragecraft.com\" target=\"_blank\"\u003eContact us\u003c\/a\u003e and our team will help you plan ahead.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"BeverageCraft","offers":[{"title":"Title","offer_id":67969965293782,"sku":"BC-3200-1-GP-ASM-USA","price":1699.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3668\/1430\/files\/Brewchill-3200H-GP__69961__93414.1787606151.jpg?v=1794504612"},{"product_id":"brewery-chiller-brewchill-pro-4000-4000-btus-usa-only","title":"Brewery Glycol Chiller - BrewChill Pro 4000 - 4000 BTUs","description":"\u003cp\u003e\u003cspan\u003e \u003cimg alt=\"icon-pdf.png\" class=\"__mce_add_custom__\" height=\"32\" src=\"https:\/\/cdn11.bigcommerce.com\/s-2pml8e\/content\/specification\/Specification_pdf.svg\" title=\"icon-pdf.png\" width=\"32\"\u003e \u003ca href=\"https:\/\/www.beveragecraft.com\/content\/specification\/glycol-chillers\/BC-4000-1.pdf\" target=\"_blank\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eOnce a brewery moves past its first year, one small glycol chiller usually isn't enough anymore. The \u003cstrong\u003eBrewChill Pro 4000-1\u003c\/strong\u003e is built for that next stage: an 18 gallon reservoir and 4,000 BTU of cooling power give you enough reach to run cooling lines out to more than one tank without the glycol warming up along the way. A vane pump keeps glycol moving to your fermenters, and the built in thermostat handles temperature swings on its own.\u003cbr\u003eThis model is a common choice for craft breweries running steady fermentation schedules, and a second pump can be added later for independent dual zone control if you need two tanks running at different temperatures. Fermenters and bright tanks up to 500 liters stay steady on the base unit, and the same reservoir and pump combination works just as well in a small winery or cidery.\u003c\/p\u003e\n\u003ch3 class=\"font-claude-response-body break-words whitespace-normal\" dir=\"ltr\"\u003e\u003cstrong\u003e\u003cspan\u003eKey Features:\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eHigh cooling capacity - 4,000 BTU\/h:\u003c\/strong\u003e Built for USA breweries running small batches, pilot systems and serious homebrew setups, the BrewChill Pro 4000-1 holds accurate temperatures in fermenters and bright tanks up to 500 liters.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eDual-zone operation (optional):\u003c\/strong\u003e Ships with one 80 gal\/hr vane pump on a 1\/3 HP motor; add a \u003ca class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.beveragecraft.com\/pumps-and-motors\/\" target=\"_blank\"\u003esecond pump\u003c\/a\u003e for dual-zone cooling and independent control across multiple tanks or processes.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eEnergy-efficient performance:\u003c\/strong\u003e A 1\/2 HP \u003ca class=\"underline underline underline-offset-2 decoration-1 decoration-current\/40 hover:decoration-current focus:decoration-current\" href=\"https:\/\/www.beveragecraft.com\/compressors-beverage-refrigeration-parts\/\" target=\"_blank\"\u003ecompressor\u003c\/a\u003e and R290 natural refrigerant keep cooling strong while holding down energy use, operating cost, and environmental impact.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eCompact, quiet, and durable build:\u003c\/strong\u003e Space-saving and quiet in operation, this chiller works well in USA microbreweries, taprooms, or home setups where noise and footprint both matter.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eEasy installation and setup:\u003c\/strong\u003e Plug-and-play with 3\/4\"NPT inlet\/outlet barbs, a 6-ft power cord and a NEMA 5-15P plug for fast setup into any USA brewing system.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eExtended line reach:\u003c\/strong\u003e Glycol lines run up to 250 ft, giving you room to place the chiller wherever it fits best in your facility.\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e\n\u003cstrong\u003eBuilt for professional brewing:\u003c\/strong\u003e An 18-gallon glycol tank and industrial-grade components keep this BrewChill unit performing reliably through continuous brewing.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003e\u003cstrong\u003eParts Included:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"[li_\u0026amp;]:mb-0 [li_\u0026amp;]:mt-1 [li_\u0026amp;]:gap-1 [\u0026amp;:not(:last-child)_ul]:pb-1 [\u0026amp;:not(:last-child)_ol]:pb-1 list-disc flex flex-col gap-1 pl-8 mb-3 print:block print:space-y-1\" dir=\"ltr\"\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e1 × BrewChill Pro 4000-1\/2-GP1 glycol chiller with 80 gal\/hr recirculation pump (1\/3 HP motor)\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e1 × External Digital Thermostat\u003c\/li\u003e\n\u003cli class=\"font-claude-response-body whitespace-normal break-words pl-2\"\u003e2 × Solenoid Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-bordered specification-tab\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch6\u003eBrewChill Pro 4000 - USA\u003c\/h6\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODEL\u003c\/td\u003e\n\u003ctd\u003eBC-4000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXIMUM DISTANCE\u003c\/td\u003e\n\u003ctd\u003eUp to 250 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003e4000 BTU\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL TANK CAPACITY\u003c\/td\u003e\n\u003ctd\u003e18 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMPRESSOR POWER\u003c\/td\u003e\n\u003ctd\u003e1\/2 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUNNING\u003c\/td\u003e\n\u003ctd\u003e12 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLUG TYPE (NEMA #)\u003c\/td\u003e\n\u003ctd\u003e5-15P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOLTAGE\u003c\/td\u003e\n\u003ctd\u003e115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREQUENCY\u003c\/td\u003e\n\u003ctd\u003e60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP TYPE\u003c\/td\u003e\n\u003ctd\u003eVane with 1\/3hp motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP\u003c\/td\u003e\n\u003ctd\u003e80 GPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF PRE-INSTALLED PUMPS\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF ADDITIONAL PUMPS\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT\u003c\/td\u003e\n\u003ctd\u003e R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT CHARGE, G (OZ)\u003c\/td\u003e\n\u003ctd\u003e 150g (5.29oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e WEIGHT GROSS\/NET\u003c\/td\u003e\n\u003ctd\u003e 158 \/ 154 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e POWER CORD LENGTH\u003c\/td\u003e\n\u003ctd\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e INLET\/OUTLET BARB, IN\u003c\/td\u003e\n\u003ctd\u003e red tube 3\/4” NPT \/ blue tube 3\/4” NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e OPERATING AMBIENT TEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e 60-90 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CLEARANCE AT LEAST\u003c\/td\u003e\n\u003ctd\u003e 12\" around the entire unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL MIXTURE, VOL%\u003c\/td\u003e\n\u003ctd\u003e40 % glycol and 60% water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNote: Installation of this item must be handled by a qualified installer in order to qualify for product return and\/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services, and possesses a business license, contractor's license and\/or resale permit. Common examples of a \"qualified installer\" include Electrician; General Contractor; Heating and Air Conditioning Specialist.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eCheck your tank count and volume against our \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-sizing-calculator\/\" target=\"_blank\"\u003ebrewery chiller sizing calculator\u003c\/a\u003e to make sure 4,000 BTU is the right size for your setup. Breweries that need more cooling capacity can compare the \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-brewchill-pro-5500-5500-btus-usa-only\/\" target=\"_blank\"\u003eBrewChill Pro 5500-2\u003c\/a\u003e, which delivers 5,500 BTU\/h and includes two pre-installed pumps. Both models have an 18-gallon reservoir. \u003ca href=\"mailto:sales@beveragecraft.com\" target=\"_blank\"\u003eContact us\u003c\/a\u003e and our team can help you decide. \u003c\/p\u003e","brand":"BeverageCraft","offers":[{"title":"BrewChill Pro 4000-1","offer_id":67969968079062,"sku":"BC-4000-1-ASM-USA","price":2049.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3668\/1430\/files\/CP-4000-1__48113__87612.1787608475.jpg?v=1794504670"},{"product_id":"brewery-chiller-brewchill-pro-5500-5500-btus-usa-only","title":"Brewery Glycol Chiller - BrewChill Pro 5500 - 5500 BTUs","description":"\u003cp\u003e\u003cspan\u003e \u003cimg alt=\"icon-pdf.png\" class=\"__mce_add_custom__\" height=\"32\" src=\"https:\/\/cdn11.bigcommerce.com\/s-2pml8e\/content\/specification\/Specification_pdf.svg\" title=\"icon-pdf.png\" width=\"32\"\u003e \u003ca href=\"https:\/\/www.beveragecraft.com\/content\/specification\/glycol-chillers\/BC-5500-2.pdf\" target=\"_blank\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe BrewChill Pro 5500-2 provides 5,500 BTU\/h of cooling capacity for fermentation and tank temperature control. It combines a 3\/4 HP compressor, an 18-gallon glycol reservoir and two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor.\u003c\/p\u003e\n\u003cp\u003eThe two-pump package includes two external digital thermostats and four solenoid valves for managing cooling demand in two tank circuits. Both circuits draw from the same reservoir and share the unit’s total cooling capacity. Size the chiller for all tanks requiring cooling at the same time.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e5,500 BTU\/h total cooling capacity:\u003c\/strong\u003e Select the unit according to your combined fermentation, cold crash and holding loads.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo pumps included:\u003c\/strong\u003e Each pre-installed vane pump is rated at 80 GPH and has its own 1\/3 HP motor. This model does not support additional pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18-gallon glycol reservoir:\u003c\/strong\u003e Holds the glycol-and-water mixture circulated through the connected cooling circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e3\/4 HP compressor with R290 refrigerant:\u003c\/strong\u003e Cools the shared glycol supply.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlycol line distances up to 450 ft:\u003c\/strong\u003e Suitability depends on tubing size, insulation, elevation, circuit resistance and cooling demand.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e115 V, 60 Hz power:\u003c\/strong\u003e Supplied with a NEMA 5-20P plug and a 6-ft power cord. Confirm electrical compatibility before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003e\u003cstrong\u003eParts Included:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e1 × Glycol Chiller with two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor\u003c\/li\u003e\n\u003cli\u003e2 x External Digital Thermostats\u003c\/li\u003e\n\u003cli\u003e4 × Solenoid Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-bordered specification-tab\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch6\u003eBrewChill Pro 5500 - USA\u003c\/h6\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODEL\u003c\/td\u003e\n\u003ctd\u003eBC-5500-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXIMUM DISTANCE\u003c\/td\u003e\n\u003ctd\u003eUp to 450 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003e5500 BTU\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL TANK CAPACITY\u003c\/td\u003e\n\u003ctd\u003e18 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMPRESSOR POWER\u003c\/td\u003e\n\u003ctd\u003e3\/4 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUNNING\u003c\/td\u003e\n\u003ctd\u003e15 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLUG TYPE (NEMA #)\u003c\/td\u003e\n\u003ctd\u003e5-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOLTAGE\u003c\/td\u003e\n\u003ctd\u003e115 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREQUENCY\u003c\/td\u003e\n\u003ctd\u003e60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP TYPE\u003c\/td\u003e\n\u003ctd\u003eVane with 1\/3hp motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP\u003c\/td\u003e\n\u003ctd\u003e80 GPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF PRE-INSTALLED PUMPS\u003c\/td\u003e\n\u003ctd\u003e 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF ADDITIONAL PUMPS\u003c\/td\u003e\n\u003ctd\u003e 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT\u003c\/td\u003e\n\u003ctd\u003e R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT CHARGE, G (OZ)\u003c\/td\u003e\n\u003ctd\u003e 150 (5.29)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e WEIGHT GROSS\/NET\u003c\/td\u003e\n\u003ctd\u003e 163 \/ 156 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e POWER CORD LENGTH\u003c\/td\u003e\n\u003ctd\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e INLET\/OUTLET BARB, IN\u003c\/td\u003e\n\u003ctd\u003e red tube 3\/4” NPT \/ blue tube 3\/4” NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e OPERATING AMBIENT TEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e 60-90 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CLEARANCE AT LEAST\u003c\/td\u003e\n\u003ctd\u003e 12\" around the entire unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL MIXTURE, VOL%\u003c\/td\u003e\n\u003ctd\u003e40 % glycol and 60% water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNote: Installation of this item must be handled by a qualified installer in order to qualify for product return and\/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services and possesses a business license, contractor's license, and\/or resale permit. Common examples of a \"qualified installer\" include Electrician; General Contractor; Heating and Air Conditioning Specialist.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eTank volume alone does not determine the required cooling capacity. Fermentation temperature control, cold crashing and holding a tank cold place different demands on the chiller.\u003c\/p\u003e\n\u003cp\u003eUse our \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-sizing-calculator\/\"\u003ebrewery chiller sizing calculator\u003c\/a\u003e to estimate your cooling load. Include the number and volume of tanks, ambient temperature, target temperature and required cooling time.\u003c\/p\u003e\n\u003cp\u003eFor help selecting a configuration or obtaining a US shipping quote, email \u003ca href=\"mailto:sales@beveragecraft.com\"\u003esales@beveragecraft.com\u003c\/a\u003e with your tank details and full delivery address.\u003c\/p\u003e","brand":"BeverageCraft","offers":[{"title":"BrewChill Pro 5500-2","offer_id":67969977942230,"sku":"BC-5500-2-ASM-USA","price":2999.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3668\/1430\/files\/CP-5500-2__49291__02176.1787610822.jpg?v=1794504896"},{"product_id":"brewery-chiller-brewchill-pro-7500-7500-btus-usa-only","title":"Brewery Glycol Chiller - BrewChill Pro 7500 - 7500 BTUs","description":"\u003cp\u003e\u003cspan\u003e \u003cimg alt=\"icon-pdf.png\" class=\"__mce_add_custom__\" height=\"32\" src=\"https:\/\/cdn11.bigcommerce.com\/s-2pml8e\/content\/specification\/Specification_pdf.svg\" title=\"icon-pdf.png\" width=\"32\"\u003e \u003ca href=\"https:\/\/www.beveragecraft.com\/content\/specification\/glycol-chillers\/BC-7500-2.pdf\" target=\"_blank\"\u003e \u003cspan\u003eSpecifications\u003c\/span\u003e\u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eThe BrewChill Pro 7500-2 delivers 7,500 BTU\/h of cooling capacity for fermentation and tank temperature control in breweries, wineries and cideries. It combines a 1 HP compressor, an 18-gallon glycol reservoir and two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor.\u003c\/p\u003e\n\u003cp\u003eThe two-pump package includes two external digital thermostats and four solenoid valves for controlling cooling demand in two tank circuits. Both circuits draw from the same chilled glycol supply and share the unit’s total cooling capacity.\u003c\/p\u003e\n\u003ch3\u003eKey Features of BrewChill Pro 7500-2 Glycol Chiller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e7,500 BTU\/h total cooling capacity:\u003c\/strong\u003e Select the chiller based on the combined load of all \u003ca href=\"https:\/\/www.beveragecraft.com\/stainless-steel-tanks\/\"\u003etanks \u003c\/a\u003erequiring cooling simultaneously.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTwo pumps included, expandable to three:\u003c\/strong\u003e Supplied with two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor, with provision for one additional pump.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e18-gallon glycol reservoir:\u003c\/strong\u003e Supplies the glycol-and-water mixture circulated through the connected cooling circuits.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e1 HP compressor with R290 refrigerant:\u003c\/strong\u003e Cools the shared glycol reservoir.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGlycol line runs up to 450 ft:\u003c\/strong\u003e Suitability depends on tubing size, insulation, elevation, circuit resistance and cooling load.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e208\/230 V, 60 Hz power:\u003c\/strong\u003e Supplied with a NEMA 6-20P plug and a 6-ft power cord. Confirm that your installation location has a compatible electrical supply before ordering.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 class=\"text-text-100 mt-2 -mb-1 text-base font-bold\" dir=\"ltr\"\u003eParts Included:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e1 × \u003cspan\u003eGlycol Chiller\u003c\/span\u003e with two pre-installed 80 GPH vane pumps, each powered by a 1\/3 HP motor\u003c\/li\u003e\n\u003cli\u003e2 x External Digital Thermostats\u003c\/li\u003e\n\u003cli\u003e4 × Solenoid Valves\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table table-bordered specification-tab\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003e\n\u003ch6\u003eBrewChill Pro 7500 - USA\u003c\/h6\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMODEL\u003c\/td\u003e\n\u003ctd\u003eBC-7500-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMAXIMUM DISTANCE\u003c\/td\u003e\n\u003ctd\u003eUp to 450 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCAPACITY\u003c\/td\u003e\n\u003ctd\u003e7500 BTU\/H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL TANK CAPACITY\u003c\/td\u003e\n\u003ctd\u003e18 gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCOMPRESSOR POWER\u003c\/td\u003e\n\u003ctd\u003e1 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRUNNING\u003c\/td\u003e\n\u003ctd\u003eWith 1 pump - 10.0 AMP\u003cbr\u003eWith 2 pumps - 12.8 AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePLUG TYPE (NEMA #)\u003c\/td\u003e\n\u003ctd\u003e6-20P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVOLTAGE\u003c\/td\u003e\n\u003ctd\u003e208\/230 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFREQUENCY\u003c\/td\u003e\n\u003ctd\u003e60 HZ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP TYPE\u003c\/td\u003e\n\u003ctd\u003eVane with 1\/3hp motor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePUMP\u003c\/td\u003e\n\u003ctd\u003e80 GPH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF PRE-INSTALLED PUMPS\u003c\/td\u003e\n\u003ctd\u003e 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e NUMBER OF ADDITIONAL PUMPS\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT\u003c\/td\u003e\n\u003ctd\u003e R290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e REFRIGERANT CHARGE, G (OZ)\u003c\/td\u003e\n\u003ctd\u003e 150 (5.29)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e WEIGHT GROSS\/NET\u003c\/td\u003e\n\u003ctd\u003e 154 \/ 147 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e POWER CORD LENGTH\u003c\/td\u003e\n\u003ctd\u003e 6 ft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e INLET\/OUTLET BARB, IN\u003c\/td\u003e\n\u003ctd\u003e red tube 3\/4” NPT \/ blue tube 3\/4” NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e OPERATING AMBIENT TEMPERATURE\u003c\/td\u003e\n\u003ctd\u003e 60-90 F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e CLEARANCE AT LEAST\u003c\/td\u003e\n\u003ctd\u003e 12\" around the entire unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLYCOL MIXTURE, VOL%\u003c\/td\u003e\n\u003ctd\u003e40 % glycol and 60% water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eNote: Installation of this item must be handled by a qualified installer in order to qualify for product return and\/or warranty coverage. Qualified Installer - Defined as a licensed professional who charges a fee for his services and possesses a business license, contractor's license and\/or resale permit. Common examples of a \"qualified installer\" include Electrician; General Contractor; Heating and Air Conditioning Specialist.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-pm-slice=\"1 1 []\"\u003eTank volume alone does not determine the required cooling capacity. Fermentation temperature control, cold crashing and holding a tank cold place different demands on the chiller.\u003c\/p\u003e\n\u003cp\u003eUse our \u003ca href=\"https:\/\/www.beveragecraft.com\/brewery-chiller-sizing-calculator\/\"\u003ebrewery chiller sizing calculator\u003c\/a\u003e to estimate your cooling load. Include the number and volume of tanks, ambient temperature, target temperature and required cooling time.\u003c\/p\u003e\n\u003cp\u003eFor help selecting a configuration or obtaining a US shipping quote, email \u003ca href=\"mailto:sales@beveragecraft.com\"\u003esales@beveragecraft.com\u003c\/a\u003e with your tank details and full delivery address.\u003c\/p\u003e","brand":"BeverageCraft","offers":[{"title":"Title","offer_id":67969979121878,"sku":"BC-7500-2-ASM-USA","price":5499.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3668\/1430\/files\/CP-7500-2__58652__91875.1787202299.jpg?v=1794504941"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0650\/3668\/1430\/collections\/CP-7500-2__58652__91875.1787202299.jpg?v=1794505366","url":"https:\/\/floridabrewing.com\/collections\/brewery-chillers.oembed","provider":"floridabrewing","version":"1.0","type":"link"}